Established in 1988, Paradigm is a leading environmental consultancy and material testing laboratory serving clients in New York and Pennsylvania and Oklahoma. Since its inception, Paradigm has excelled in offering thoughtful solutions to address today’s complex environmental concerns. Utilizing a team approach, Paradigm provides architects, engineers, building owners, industrial clients, and contractors with advice, integrated strategy and value added services to confront environmentally related problems.
CLIENT RESOURCES
Click the tabs below to get started.
Frequently Asked Questions
Downloadable Forms
Use of these forms is subject to Paradigm’s Terms and Conditions.
PLM TEM Bulk Asbestos Chain of Custody: PDF | Excel
Paradigm Chain of Custody: PDF | Excel
Glossary
[glossary cat=”paradigm” glossary index style=”classic-definition” glossary_search=”0″]Sampling
Here at Paradigm, we believe that you can’t get good data out of bad samples. It is our pleasure to share our expertise on sampling procedures to ensure that our clients get what they need.
EPA Method 5035A Sampling Summary (VOCs in Soil/Solid Matrix)
5035A is a complex sampling & preparatory procedure. There are several other variations not noted here. Please call your Paradigm Customer Service representative to discuss your particular situation if you have questions at (585) 647-2530. For quality control reasons, any unused kits can not be returned for credit. Kits will be charged at the time of container pick up.
3 tared 40 ml VOA vials (two empty with stir bars for low-level and one empty amber vial without stir bar for high-level analysis (if needed)
1 empty VOA vial (for moisture determination, labeled “evaporative loss”)
1 disposable soil coring tool, for nominal 5 gm sample collection
For each sampling location, fill the coring tool with the sample and push one core into each 40ml VOA vial (for a total of four per sample location). Clean and close each vial securely with a Teflon-lined cap.
(NOTE: if an MS/MSD is needed, use one additional kit for that location).
All VOA vials have been coded, pre-labeled and PRE-WEIGHED. DO NOT ADD A LABEL or any tape, or we will not be able to determine the sample weight.
Dispose of the coring tool. Do not re-use for any other locations.
Bring the samples on ice to the lab ASAP, but NOT TO EXCEED 48 Hours from time of sampling, otherwise holding times will be violated. The lab will freeze the samples upon log-in, and has up to a total of 14 days from sampling to analysis.
FROM THE BLOG
Keeping you informed with the latest industry & company news.
EPA Turns Over Ownership to Diaz Homes in Holley
by Kristina Gabalski | May 8, 2017 | This article originally appeared in West Side News VHDC President Daniel Schiavone and [...]
Paradigm Trains 29 Underserved City Residents for Full-Time Employment
Paradigm Environmental is proud to have been a partner employer in the City's Rochester Environmental Job (REJob) Training Program. [...]
Federal Judge Strikes Down Obama Administration’s Fracking Rules
By Camilla Domonoske | Jun 22, 2016 | This article originally appeared in NPR A federal [...]